Viking 100kW Auto Load Shedding Load Bank

Viking 100kW Auto Load Shedding Load Bank including INTEGRATED PLC CONTROLLER WITH COLOUR TOUCH SCREEN, IP65 STAINLESS STEEL LOAD RESISTORS AND MORE.

1 in stock

SKU: VPS10S-LBR-PLC/100A Categories: , , ,

Description

Viking  100kW Auto Load Shedding Load Bank – VPS10S-LBR-PLC/100A

Viking 100kW Auto Load Shedding Load Bank features: 

AUTO CONNECT & DISCONNECT OF LOAD STEPS TO MAINTAIN PRESET GENERATOR LOADING
CONTINUALLY MONITORS EXTERNAL GENERATOR LOAD TO PREVENT UNDER OR OVER LOADING
MANUAL LOAD TESTING FACILITY
MULTI FUNCTION PLC COLOUR TOUCHSCREEN
IP65 STAINLESS STEEL LOAD RESISTORS
CIRCUIT BREAKER LOAD STEP PROTECTION
OVER TEMPERATURE & FAN FAIL PROTECTION
STAINLESS STEEL GRILLE & FASTERNERS

SPECIFICATIONS

DIMENSIONS: Standard : H:1135 mm W:780 mm D:940 mm                                                                                                     Installation base(Option): H:1260 mm W:845 mm D:940 mm
UNIT WEIGHT: Standard: 242 KG        Installation base: 254KG
LOAD RATING: 100KW @ 400 volt AC /- 10%, 50Hz, 3 wire connection (Other voltages and Hz ratings available)
LOAD SELECTION: PLC controlled 4 step loading in 5kW increments to maintain programmed generator KW load
LOAD STEPS: Four load steps 1x 10kW, 1x 20kW, 1x 30kW & 1x 40kW
DIGITAL METERING: Backlit LCD for Volts, Amps KW, KVA, KWH, PF with RS-485 Mod-Bus communication
RESISTOR WIRING: 200 degree C rated silicone insulated
LOAD CABLE CONNECTIONS: Shielded terminal links with 1 x M8 bolted connections per phase
FAN MOTOR: 1.1KW, 400 VOLT /- 10%, 50Hz ,6 pole TEFC, IP54. DOL start with thermal overload
FINISH: Grey/black UV stabilised Powder Coat with stainless steel discharge grille and fasteners
ENCLOSURE: IP54 (control panel door closed)

OPTIONS:

BOX FRAME: 50 x 50mm hollow box protection frame with two point top lift (black powder coat finish)
INSTALLATION BASE: Steel C section mounting rails for permanent installation (black powder coat finish)
POWERLOCK: Powerlock twist type shielded connectors for incoming power supply (400 amp rated)
DIGITAL METERING: Backlit LCD for Volts, Amps KW, KVA, KWH, PF with RS-485 Mod-Bus communication
CUSTOM STEP SIZE AND LOADING: Custom kW step sizes and number. Minimum step size is 5KW and maximum step number is five (5)